Guaranteed magnetic values
Please cklick on our grades in order to see the curves of our typical values.
Grade
Thickness*
Maximum
coreloss
at
Typical
coreloss
at
Polarisation
at
PowerCore®
mm
1.5 T
50Hz
W/kg
1.7T
50Hz
W/kg
1.5 T
60Hz
W/lb
1.7 T
60Hz
W/lb
1.5 T
50Hz
W/kg
1.7 T
50Hz
W/kg
1.5 T
60Hz
W/lb
1.7 T
60Hz
W/lb
800 A/m
min. T
800 A/m
typ. T
H 085-23
0.23
0.85
0.51
0.81
0.49
1.88
1.91
H 090-23
0.23
0.9
0.54
0.86
0.52
1.88
1.91
H 095-23
0.23
0.95
0.57
0.91
0.55
1.88
1.89
H 100-23
0.23
1
0.6
0.96
0.58
1.85
1.88
H 090-27
0.27
0.9
0.54
0.87
0.52
1.88
1.91
H 095-27
0.27
0.95
0.57
0.92
0.55
1.88
1.91
H 103-27
0.27
1.03
0.62
0.97
0.58
1.88
1.89
H 105-30
0.30
1.05
0.63
1.02
0.61
1.88
1.91
H 111-30
0.30
1.11
0.66
1.06
0.64
1.88
1.9